Almost everyone has one on the front door, and almost nobody has thought about what is inside it. The motor in a smart lock runs for half a second at a time, a few times a day, and then sits idle for the rest of the year. That single fact rearranges the whole selection: efficiency over a run barely matters, torque is smaller than intuition suggests, and the parameter that decides whether the product survives its warranty is the current drawn while nothing is happening. The lock is also the one application in this catalogue where the motor must not hold its position, which is the opposite of what every other mechanism wants.

The Motor Turns a Clutch, Not the Deadbolt

The obvious mental model, a motor pushing a steel bolt into a strike plate, is the wrong one. Pushing a deadbolt takes real force, and no 12 mm gear motor is going to do it on four AA cells for a year. What actually happens is that the motor drives a clutch inside the lock body.

The outside handle is permanently disconnected from the latch. When a valid credential arrives, the motor moves for a fraction of a second and brings the clutch into engagement, which links the handle to the latch mechanism. You turn the handle, the door opens, and the clutch drops back out. The motor never sees the force of the latch, only the force needed to move the clutch and compress the small spring that returns it.

That is why the torque figures look so modest. A ZGA12FT in its 6V build is quoted at 115 rpm and 175 gf·cm, which is about 17 mN·m. At that speed the output is roughly 0.2 W, consistent with the 0.5 W input rating. Seventeen millinewton meters will not move a deadbolt, and it does not have to. What it must do is overcome the clutch spring reliably at the coldest temperature the door will see, and return to the disengaged position when the power is removed.

Half a Second of Running, a Year of Waiting

A household lock cycles perhaps ten times a day. At half a second per cycle that is five seconds of running daily, or about thirty minutes across a year. The other 8,760 hours are spent waiting, and the waiting is where the battery goes.

The arithmetic is blunt. Four alkaline AA cells give roughly 2,000 mAh at 6V. Running at 80 mA for thirty minutes a year consumes about 0.04 Ah, which is two percent of the pack. A standby current of 50 microamps would drain the same pack in about four and a half years, so the running load is irrelevant beside it. Raise the standby current to 500 microamps and the same cells last five months. Ten times the standby current costs nine tenths of the battery life, while the motor’s own consumption never enters the calculation.

This is why a lock motor is selected on its behavior at zero speed and its behavior in the first few milliseconds of a cycle, not on its efficiency curve. It is also why a low-voltage brushed motor with no driver electronics competes so well here: a brushless equivalent needs a controller that draws standing current of its own, and in a product that spends a year asleep, that controller is a larger load than the motor will ever be.

Why This Motor Must Not Hold Its Position

Every other application in this catalogue wants the load held when the power goes off. A roller blind must not drop, a gate must not swing, a linear actuator must not creep. A door lock wants exactly the reverse, and getting it wrong turns a convenience feature into a safety problem.

If the clutch stayed engaged after the cycle, the outside handle would stay connected to the latch, and the door would open to anyone who turned it, with or without a credential. The design intent is that a spring holds the clutch disengaged and only the motor can bring it across, so a dead battery or a failed controller fails toward locked rather than open.

That rules out the gearbox type every other application wants. A worm reducer, ideal for holding a load, resists exactly the return motion the clutch spring has to perform, and any stage that stays put by friction blocks it too. A spur or planetary stage with low detent torque lets the spring do its job.

The manual key path is the check on all of this. With the battery removed, a key must still open the door, and the mechanism that allows it usually bypasses the clutch entirely. Any motor and gearbox combination that could trap the clutch in engagement also traps the customer outside, and that is the failure a lock cannot have.

Reading a Stall as a Position

The controller has no position sensor on the clutch. It knows the motor has reached the end of its travel when the current rises into the stall region, and it stops the drive on that signal. This is the same principle as the vending dispenser, with a shorter window: the move is expected to complete in a few hundred milliseconds, so the current has to rise predictably at the end of it.

Two failure modes come out of that. A mechanism that is slightly stiff, from cold grease or a door that has settled, reaches the stall threshold before the clutch is fully engaged, and the lock reports success while the handle remains disconnected. A mechanism that is too free never reaches it at all, and the controller times out having driven further than the clutch permits. Both are cured by the same thing: a motor whose current-torque relationship is tight and repeatable, and a stall threshold set with margin at both ends.

Cold, Ice and a Door That Has Moved

Two environmental effects dominate field returns, and neither appears in a lab test at room temperature.

The first is cold. At minus twenty the grease stiffens and the clutch spring is stiffer than at twenty above, so breakaway torque rises just as the battery’s internal resistance rises and its terminal voltage sags. The motor sees less voltage at the moment it needs more torque, which is why a lock specified from a 25 degree datasheet can fail on the first cold morning of the year.

The second is that doors move. A door swollen with damp or dropped on worn hinges misaligns the latch with the strike plate, and the extra friction lands on the mechanism the clutch is moving. The motor cannot tell a stiff clutch from a misaligned door, and both look like a lock that works in summer and jams in winter.

What to Send With the Enquiry

Five figures settle most of a lock design: the voltage available from the cell pack, the torque needed to move the clutch against its spring at the coldest specified temperature, the cycle count per day, the standby current the electronics allow, and whether the mechanism must disengage on loss of power. The last one is not negotiable, but it is worth stating explicitly, because it eliminates gearbox types that would otherwise look attractive on torque and efficiency.

The one figure worth arguing about is the breakaway torque at the cold extreme, not the rated torque at room temperature. It is the number that decides whether the lock opens on a January morning, it is never on a catalogue page, and it is the one a customer discovers only after a hundred of them have been returned.

What Motor Does a Smart Door Lock Need?